1. Equipment Inspection: Before use, inspect the pneumatic camera tower to ensure it is in good condition and all components are functioning properly.
2. Securing the Equipment: Secure the pneumatic camera tower to a tripod or vehicle, ensuring it is securely mounted.
3. Connecting the Air Source: Connect the air inlet of the control valve to the air compressor and the air outlet to the mast.
4. Adjusting the Pressure: Turn on the air compressor and adjust the pressure regulator so that the pressure gauge reads 0.2 MPa.
5. Raising and Lowering: Pull the lift control valve handle to begin raising the mast. If you need to stop at a certain height, move the handle to the middle position.
6. Lowering: To lower the mast, pull the lift control valve handle downward.