1. Check Guy Cable and Connection Point Condition
Confirm that all guy cables are free of broken strands, rust, deformation, or loosening.
Check that the ground stakes are secure and that the tower's anchor points are free of cracks or loosening, ensuring a safe structural foundation.
2. Check Tower Verticality
Use a level or plumb line to measure the tower's verticality. If tilted, record the direction of deviation as a basis for adjustment.
3. Adjust Tension Diagonally Simultaneously
Locate the turnbuckles (double-threaded adjustment clips) in the guy cables and simultaneously rotate both ends with a wrench.
Tighten clockwise to increase tension and loosen counterclockwise to decrease tension.
Adjustment must be done simultaneously on two diagonally opposite lines (e.g., adjust the northeast and southwest directions first) to avoid unilateral stress that could cause structural deformation.
4. Measure and Equalize Tension
Use a tension meter to measure the tension value of each guy cable, ensuring that the tension difference between each cable does not exceed 10%. In areas with strong winds, the initial tension can be appropriately increased to 1.2 times the standard value to enhance wind resistance.
5. Tightening and Anti-loosening Measures
After adjustment, immediately tighten the anti-loosening nuts on the turnbuckles to prevent tension from loosening due to equipment vibration.
6. Re-inspection and Recording
Use a level again to check if the tower body has returned to verticality, making minor adjustments if necessary.
Fill out the inspection record, including tension values, environmental conditions, and operator information, for future traceability.